Innovative design, revolutionary ergonomics, advanced technology. RXDC – HyperSphere technology brings the best of DC X-ray units into your surgery.
- Maximum flexibility
- Precision x-ray imaging
- Innovative ergonomics
- Complete reliability
Innovative design, revolutionary ergonomics, advanced technology. RXDC – HyperSphere technology brings the best of DC X-ray units into your surgery.
The tube revolves freely around the joint, allow it to reach practically any position, including the vertical. RXDC – HyperSphere technology also features an automatic touch-sensitive device for simple, efficient locking/release of the X-ray head tube so it can be repositioned effortlessly between one exposure and the next. Ergonomic zones on the sides of the head provide a firm grip for effective positioning.
Access to exposure programmes is provided via two simple settings. The large display shows the sequential exposure monitor and the patient exposure dose; moreover, the controller has a wireless X-ray snapshot button. Wireless device control allows fast, easy installation: no fixed control panels are required, thus providing greater freedom when positioning the X-ray unit.
With a tiny focal spot of 0.4 mm (at 30 cm), RXDC – HyperSphere technology produces sharp images under any condition. The tube head is now even more powerful as it operates at 70 kV, 8 mA. RXDC – HyperSphere technology gives your surgery the precision and quality of cuttingedge know-how.
The constant potential high frequency (DC) generator reduces the most harmful low energy radiation that is characteristic of analogue (AC) generators: current is adjustable (from 8 mA to 4 mA), as are exposure times.
Moreover, the long cone (30 cm) with incorporated rectangular collimator reduces the exposed surface area. This maximises image quality and safeguards patient and worker health.
TECHNICAL DATA | ||
---|---|---|
Generator | Constant potential, microprocessor-controlled | |
Working frequency | 145-230 KHz (typically 175 KHz) | |
Focal spot | 0,4 mm (IEC 336) | |
Anode current | 4 / 8 mA | |
Voltage at X-ray tube | 60 / 65 / 70 kV (*) | |
Exposure time | 0.020 – 1.000 seconds, R’10 and R’20 scale | |
Source-skin distance | 20 e 30 cm | |
Irradiated field | 35 x 45 mm rectangular, Ø 55 mm and Ø 60 mm round | |
Additional collimators | 31 x 41 mm and 22 x 35 mm, for size 2 and size 1 sensors | |
Total filtration | 2.0 mm Al @ 70kV | |
Power supply | 50/60 Hz, 115-120Vac ±10% o 230-240Vac ±10% | |
Duty Cycle | continuous operation with self-adjustment up to 1s/80s total | |
Stability | Automatic lock/release, with touch-sensitive activation (HyperSphere technology) | |
Arms | Available in 3 lengths: 40 cm – 60 cm – 90 cm | |
Max. arm extension | 230 cm, from wall | |
Certification | CE 0051, FDA approved |